/  Design Of Electric Switchboards (lV and MV) Only Of Design and Engineering Engineers Training

Design Of Electric Switchboards (lV and MV) Only Of Design and Engineering Engineers Training

BMC Training provides a training course in Design Of Electric Switchboards (lV and MV) Only Of Design and Engineering Engineers in Electrical and Power Engineering Training

Course Title
Venue
Start Date
End Date
  • Istanbul
    12 - 7 - 2020
    16 - 7 - 2020
  • Bali
    12 - 7 - 2020
    16 - 7 - 2020
  • Singapore
    12 - 7 - 2020
    16 - 7 - 2020
  • Washington
    12 - 7 - 2020
    16 - 7 - 2020
  • Istanbul
    19 - 7 - 2020
    23 - 7 - 2020
  • Bali
    19 - 7 - 2020
    23 - 7 - 2020
  • Singapore
    19 - 7 - 2020
    23 - 7 - 2020
  • Washington
    19 - 7 - 2020
    23 - 7 - 2020
  • Dubai
    26 - 7 - 2020
    30 - 7 - 2020
  • Paris
    26 - 7 - 2020
    30 - 7 - 2020
  • Hong Kong
    26 - 7 - 2020
    30 - 7 - 2020
  • Kuala Lumpur
    2 - 8 - 2020
    6 - 8 - 2020
  • Rome
    2 - 8 - 2020
    6 - 8 - 2020
  • Barcelona
    2 - 8 - 2020
    6 - 8 - 2020
  • Zurich
    2 - 8 - 2020
    6 - 8 - 2020
  • London
    9 - 8 - 2020
    13 - 8 - 2020
  • Madrid
    9 - 8 - 2020
    13 - 8 - 2020
  • Munich
    9 - 8 - 2020
    13 - 8 - 2020
  • Berlin
    9 - 8 - 2020
    13 - 8 - 2020
  • New York
    9 - 8 - 2020
    13 - 8 - 2020
  • Dubai
    16 - 8 - 2020
    20 - 8 - 2020
  • Paris
    16 - 8 - 2020
    20 - 8 - 2020
  • Hong Kong
    16 - 8 - 2020
    20 - 8 - 2020
  • Istanbul
    23 - 8 - 2020
    27 - 8 - 2020
  • Bali
    23 - 8 - 2020
    27 - 8 - 2020
  • Singapore
    23 - 8 - 2020
    27 - 8 - 2020
  • Washington
    23 - 8 - 2020
    27 - 8 - 2020
  • London
    27 - 9 - 2020
    1 - 10 - 2020
  • Madrid
    27 - 9 - 2020
    1 - 10 - 2020
  • Munich
    27 - 9 - 2020
    1 - 10 - 2020
  • Berlin
    27 - 9 - 2020
    1 - 10 - 2020
  • New York
    27 - 9 - 2020
    1 - 10 - 2020
  • Istanbul
    6 - 9 - 2020
    10 - 9 - 2020
  • Bali
    6 - 9 - 2020
    10 - 9 - 2020
  • Singapore
    6 - 9 - 2020
    10 - 9 - 2020
  • Washington
    6 - 9 - 2020
    10 - 9 - 2020
  • Kuala Lumpur
    13 - 9 - 2020
    17 - 9 - 2020
  • Rome
    13 - 9 - 2020
    17 - 9 - 2020
  • Barcelona
    13 - 9 - 2020
    17 - 9 - 2020
  • Zurich
    13 - 9 - 2020
    17 - 9 - 2020
  • Dubai
    20 - 9 - 2020
    24 - 9 - 2020
  • Paris
    20 - 9 - 2020
    24 - 9 - 2020
  • Hong Kong
    20 - 9 - 2020
    24 - 9 - 2020
  • Kuala Lumpur
    18 - 10 - 2020
    22 - 10 - 2020
  • Rome
    18 - 10 - 2020
    22 - 10 - 2020
  • Barcelona
    18 - 10 - 2020
    22 - 10 - 2020
  • Zurich
    18 - 10 - 2020
    22 - 10 - 2020
  • London
    25 - 10 - 2020
    29 - 10 - 2020
  • Madrid
    25 - 10 - 2020
    29 - 10 - 2020
  • Munich
    25 - 10 - 2020
    29 - 10 - 2020
  • Berlin
    25 - 10 - 2020
    29 - 10 - 2020
  • New York
    25 - 10 - 2020
    29 - 10 - 2020
  • Dubai
    4 - 10 - 2020
    8 - 10 - 2020
  • Paris
    4 - 10 - 2020
    8 - 10 - 2020
  • Hong Kong
    4 - 10 - 2020
    8 - 10 - 2020
  • Istanbul
    11 - 10 - 2020
    15 - 10 - 2020
  • Bali
    11 - 10 - 2020
    15 - 10 - 2020
  • Singapore
    11 - 10 - 2020
    15 - 10 - 2020
  • Washington
    11 - 10 - 2020
    15 - 10 - 2020
  • London
    15 - 11 - 2020
    19 - 11 - 2020
  • Madrid
    15 - 11 - 2020
    19 - 11 - 2020
  • Munich
    15 - 11 - 2020
    19 - 11 - 2020
  • Berlin
    15 - 11 - 2020
    19 - 11 - 2020
  • New York
    15 - 11 - 2020
    19 - 11 - 2020
  • Istanbul
    22 - 11 - 2020
    26 - 11 - 2020
  • Bali
    22 - 11 - 2020
    26 - 11 - 2020
  • Singapore
    22 - 11 - 2020
    26 - 11 - 2020
  • Washington
    22 - 11 - 2020
    26 - 11 - 2020
  • Kuala Lumpur
    1 - 11 - 2020
    5 - 11 - 2020
  • Rome
    1 - 11 - 2020
    5 - 11 - 2020
  • Barcelona
    1 - 11 - 2020
    5 - 11 - 2020
  • Zurich
    1 - 11 - 2020
    5 - 11 - 2020
  • Dubai
    8 - 11 - 2020
    12 - 11 - 2020
  • Paris
    8 - 11 - 2020
    12 - 11 - 2020
  • Hong Kong
    8 - 11 - 2020
    12 - 11 - 2020
  • Kuala Lumpur
    20 - 12 - 2020
    24 - 12 - 2020
  • Rome
    20 - 12 - 2020
    24 - 12 - 2020
  • Barcelona
    20 - 12 - 2020
    24 - 12 - 2020
  • Zurich
    20 - 12 - 2020
    24 - 12 - 2020
  • London
    27 - 12 - 2020
    31 - 12 - 2020
  • Madrid
    27 - 12 - 2020
    31 - 12 - 2020
  • Munich
    27 - 12 - 2020
    31 - 12 - 2020
  • Berlin
    27 - 12 - 2020
    31 - 12 - 2020
  • New York
    27 - 12 - 2020
    31 - 12 - 2020
  • Dubai
    13 - 12 - 2020
    17 - 12 - 2020
  • Paris
    13 - 12 - 2020
    17 - 12 - 2020
  • Hong Kong
    13 - 12 - 2020
    17 - 12 - 2020
  • Istanbul
    6 - 12 - 2020
    10 - 12 - 2020
  • Bali
    6 - 12 - 2020
    10 - 12 - 2020
  • Singapore
    6 - 12 - 2020
    10 - 12 - 2020
  • Washington
    6 - 12 - 2020
    10 - 12 - 2020

Course Description

Switchgear (and circuit breakers) are obviously critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. The two day workshop will discuss application, installation, maintenance and testing issues relating to medium and high voltage switchgear and circuit breakers.

There will also be a coverage of low voltage switchgear. You will receive a thorough grounding in switchgear theory and standards. You will gain a solid understanding of the issues associated with the proper application, installation and maintenance of these critical items of equipment with an overriding emphasis on safety.

This comprehensive five day workshop emphasises medium voltage switchgear which represents most of the switchgear installed on electrical distribution systems. The focus here is on air blast, oil, SF6 and vacuum circuit breakers. Case studies covering the main manufacturer's equipment will illustrate the important practical principles. Other power system protection components will be discussed as well to ensure that switchgear is understood in the correct context.

Course Objectives

Delegates will learn about the following:

  • Selection of appropriate type and rating of circuit breakers and switchgear.
  • Fundamentals of operation of switchgear. Switchgear components (CTs, VTs, relays, cable terminations)
  • Safe operational policies including safety rules and safety documents.
  • Able to discuss different LV for of separations. Fully understand how to size and select different type of motor starters.
  • Diagnostic tools and test equipment for switchgears.
  • Safe maintenance policies including safe working in switch rooms, indoor and outdoor substation

Course Outlines

  • Introduction to LV & HV Switchgear.
  • Breaking of AC currents
  • Transient restrike recovery voltage (TRRV). Surge arresters.
  • Metal clad & metal enclosed switchboards.
  • LV forms of separation.
  • Load flow studies (rated current).
  • Calculation of fault currents (simplified methods, PU, MVA & Symmetrical components). Breaking & Making Capacities.
  • Different types of LV Circuit breakers/contactors (ratings &tripping units/curves).
  • Sizing of motor starters (DOL, Star/Delta, Auto transformer & soft starters).
  • Fuse sizing for distribution transformers & motors.
  • Type 1 & type 2 co-ordination for motor starters. Dimensioning of LV switchboards (MCC & power centers). Different types of HV Circuit breakers (Oil, Vacuum, Gas & Air type)
  • Merits & demerits of each type of HV breakers. Different de-rating factors (temperature, altitude, etc …).
  • Breaking capacity de-ratings according to IEC/ANSI C37.010.
  • Bus bar sizing/cross sectional area/current density & skin effect.
  • Specifications for switchboards.
  • Overview of protection & measuring units. Different types electrical diagrams.
  • Panel scheduling.
  • Type & routine tests on switchgear.
  • Course Evaluation & Summary

Courses Search

Recent Posts

Connect with us

IFRS Preparation. (5 Days)Available in London - Dubai - Istanbul - Kuala Lumpur

Join our Civil and Construction Engineering Training Courses , Electrical and Power Engineering Training Courses and Facilities Management Training

Technical Training Courses

Newsletter